Product
Contact Information
E-mail:
Telephone:
Address:
Building 31, Sino-German Industrial Park, Yibin District, Luoyang City, Henan Province
QGD10-Z20 Energy-Storage-Type Starting Power Supply Unit
Classification:
Product Description
Purpose
The QGD-10-Z20 energy-storage‑type starting power unit is primarily used to supply electrical power for the starting of engines and for field maintenance of helicopters in the Z‑8, Z‑10, Z‑20, Z‑20T, Mi‑171, and other series. Its power output complies with the relevant requirements specified in GJB 3706‑1999, “Power Supply Characteristics and General Requirements for Military Helicopter Ground Power Units.”
The QGD-10-Z20 energy‑storage‑type starting and power‑supply unit is a modular, mobility‑enhanced upgrade based on the QGD-10(Z) energy‑storage‑type starting and power‑supply unit. It comprises two variants: the QGD-10‑Z20/28V energy‑storage‑type starting and power‑supply unit, intended for starting the engines of the Z‑10 helicopter series and providing power during field maintenance; and the QGD-10‑Z20/115V AC/DC energy‑storage‑type starting and power‑supply unit, designed for engine starting and field‑maintenance power supply on helicopters such as the Z‑8, Z‑20, Z‑20T, and Mi‑171.
Main Parameters of the QGD-10-Z20/28V Energy-Storage-Type Starting Power Supply Unit
Main Technical Parameters
(1) Host external dimensions (main body, L×W×H): 650 mm × 540 mm × 380 mm;
(2) Weight: 70 kg;
(3) Rated output voltage: DC 28.8 V;
(4) Rated output current: 1800 A;
(5) Maximum output current: 3000 A at 0.5 s;
(6) Nominal battery capacity: 120 Ah;
(7) Battery capacity: 3400 Wh;
(8) Operating temperature: -40°C to +60°C.
Schematic Diagram of Structure and Appearance

Main Parameters of the QGD-10-Z20/115V Energy-Storage-Type Starting Power Supply Unit
The QGD-10-Z20/115V energy-storage-type starting power supply unit consists of an energy-storage module and an AC 115V power supply module.
Technical Specifications of the Energy Storage Unit
(1) Rated voltage: DC 270 V;
(2) Output voltage range: DC 180 V to DC 285.6 V; DC 28 V;
(3) Rated capacity: ≥6.4 kWh;
(4) Rated output power: DC 270 V / 10 kW; DC 28 V / 1000 W;
(5) Peak output power: 20 kW;
(6) Charging current: 12 A;
(7) Charging time: ≤3h;
(8) External dimensions: L650×W540×H380mm
(9) Weight (including modular battery): 80 kg.
Technical Specifications of the 115V AC Power Supply Unit
(1) Input voltage range: DC 180 V to DC 300 V;
(2) Output voltage: AC 115 V / 400 Hz (three-phase four-wire);
(3) Rated output power: 10 kVA, with a 2× overload capability for 5 seconds;
(4) External dimensions: L650×W540×H300mm;
(5) Weight: 40 kg.
Schematic Diagram of Structure and Appearance

Operating environment
The operating environmental conditions for the equipment are as follows:
| Serial number | Project | Category | Content | Note |
| 1 | Environmental parameters | Operating temperature | -40℃~+60℃ | |
| 1 | Environmental parameters | Maximum relative humidity | (85±5)% (30℃~60℃) | |
| 2 | Input parameters of the accompanying charger | Scope | AC220V/50Hz |
Online consultation
Leave your contact information to get a free product quote
Related Products